Installation Kit with High Flow Filter

Installation Kit with High Flow Filter

£129.00
(Exc. 20% VAT)
(£154.80 Inc. VAT)
In stock, immediate despatch
+

Installation Kit with High Flow Filter

This high flow installation kit is suited to any water cooler that produces over 60 litres per hour. 

Component overview 
1. 15mm Compression Equal Tee (brass) (CONT15) 
1a.  15mm Compression Equal Elbow (brass). To use when the mains pipe is in a vertical position, so that the Water Block can be installed vertically (it does not work in a horizontal position) (CONE15) 
2. Installation Rail, consisting of 
a) Short length 15 mm copper tubing to connect to Equal Tee (or Equal Elbows) 
b) 15mm Compression Double Check Valve with isolation tap (VCD) 
c) Pressure Reducing Valve set at 2.5 to 3 bar (PRV) 
d) Water Block (non-return valve and safeguards against flooding. (See below about the water block). MUST BE INSTALLED VERTICALLY POINTING DOWNWARDS (WBLOC) 
e) John Guest ¾” BSP to 3/8” push-fit reducer (REDU3438) 
f) High capacity Carbon Fibredyne Filter Candle (FILTBCM) 
g) Green (re-usable) Filter Housing (FILTHOUBCM) 
h) Filter Housing Spanner to tighten the Filter Housing Seal 
(FILTHOUBCMKEY) leave Spanner with the Filter. 
i) 3metres of 5/16” John Guest Tube (TUBE516) 
j) Filter Head 3/8” for Filter HOU BCM (FILTHEADBCM) 
k) 3x 3/8” Stem OD to 5/16” Push Fit adapters (ADAP38516) 

 

How to connect the Installation Kit

1. Isolate water supply at stop cock or isolation valve. 
2. Cut the copper pipe leaving enough room to install your T-piece or elbow compression fitting 
(The use of clips to support the pipe work is recommended).  
3. Then install the PFRAILKITCON  Remembering that the Water Block must be in a vertical position 
pointing down.                                                                                                                                                                  
4. Thoroughly check all pipe work for leaks before commissioning 

 

About the Water Block 
The Water Block is designed to prevent large scale flooding by limiting the 
amount of water (dependent upon the setting) that passes through in one 
flow. The Water Block should be installed in a vertical position with the flow 
direction pointing down. 
To set the flow meter on the Water Block use the white key provided to 
move the arrow to number 1 on the inside of the rim. This will limit the flow 
to 4.5 ltr. If the arrow points to 2, the flow will be limited to 9 ltr etc. 
In the event that the water block shuts the water off the pink button in the 
centre of the block will pop out. Simply depress the button to reset